IDN 3014 (P-0-3014) Probe Difference Control Parameter




Data Length:  | 2 bytes  | Non-Volatile:  | No  | 
Data Type:  | Unsigned decimal  | Write Access:  | CP2, CP3, CP4  | 
Minimum:  | 0  | Run-Up Check:  | 
  | 
Maximum:  | 6  | Cyclic Transfer:  | 
  | 
Default:  | 0  | Serial Equiv:  | 
  | 
Units:  | 
  | Version:  | |
IDN Type:  | VE  | ADS Index Group (hex.):  | 0x8BC6  | 
Definition:
Value  | Description  | 
|---|---|
0  | Difference probe edge function is off  | 
1  | Compute distance between one positive edge and one negative edge  | 
2  | Compute distance between one negative edge and one positive edge  | 
3  | Compute distance between two successive positive edges  | 
4  | Compute distance between two successive negative edges  | 
5  | Compute distance between the first positive and negative edge  | 
6  | Compute distance between the first negative and positive edge  |