Field-configurable cable, connector, and accessories

ZB7306-xxxx cable

Field-configurable cable, connector, and accessories 1:

The configurable ZB7306-xxxx system cable is used to connect the AMP8000 system components AX883x, AMP8620, AMP8805, and AMP8yxx

EtherCAT P cable, no overall shield, PUR, drag-chain suitable, 3G 2.5 mm² + 2 x 1.5 mm (1 x 4 x AWG22), black with red stripe, OD = 11.9 mm (±0.4 mm)

ZK7A33-3100-0xxx cable

The pre-assembled ZK7A33-3100-0xxx power cables are used to connect the AMP8620 to the supply voltage.

ZK7000-0101-0xxx cable

Field-configurable cable, connector, and accessories 2:

The pre-assembled ZK7000-0101 EtherCAT P cable is used for the connection of the AMP8000 system components AMP8620 and AMP8805 with other EtherCAT P devices.

Cable ZK1090-0132-0005

The pre-assembled EtherCAT cable ZK1090-0132-0005 provides the connection between the fieldbus input of the AMP8620 power supply module and other EtherCAT devices.

B23 connector

In the following you will find an overview of which connectors are available.

Field-configurable cable, connector, and accessories 3:

The ZS7300-0027 connector for field assembly is used to connect the mains supply cable to X01 of the AMP8620 power supply module.
Mechanical coding 3 of the connector must be provided for this purpose.

Field-configurable cable, connector, and accessories 4:

The ZS7300-0002 connector for field assembly is used to connect the system input or motor input to the ZB7306-xxxx EtherCAT P cable.
Mechanical coding 3 of the connector must be provided for this purpose.

Field-configurable cable, connector, and accessories 5:

The ZS7300-0001 connector for field assembly is used to connect the system output to the ZB7306-xxxx EtherCAT P cable.
Mechanical coding 3 of the connector must be provided for this purpose.

Field-configurable cable, connector, and accessories 6:

The ZS7300-0022 connector for field assembly is used to connect the braking resistor to X71 of the AMP8620 power supply module.
Mechanical coding 2 must be provided for this purpose.

Crimp contacts

Field-configurable cable, connector, and accessories 7:

The crimp contacts are available as pins and sockets in various designs:

Ordering information

Description

ZS7000-C001

Ethernet element, male, AWG22/0.34 mm²

ZS7000-C002

Ethernet element, female, AWG22/0.34 mm²

ZS7000-C010

B23, female, 4 mm², for AMP8620 X01

ZS7000-C015

B23, male, 1.5 mm²

ZS7000-C016

B23, female, 1.5 mm²

ZS7000-C017

B23, male, 2.5 mm²

ZS7000-C018

B23, female, 2.5 mm²

Crimping tool

Field-configurable cable, connector, and accessories 8:

With the ZB8810-0000 crimping tool, you can crimp the following components, for example:

Crimping insert

Field-configurable cable, connector, and accessories 9:

The ZB8810-0002 crimping insert and locator is suitable for: