Coupling

Notice

Damage caused by rigidly coupled coil units

Rigidly coupled coil units can cause non-synchronous movements which can lead to tension and damage to the mechanical system and the coil unit.

  • Ensure that the coupled coil units move synchronously

Notice

Damage due to series connection of the coil units

Connecting the coil units in series can cause the cables to burn. This can damage the coil unit and connected components.

  • Coil units should only be coupled in a parallel connection. Series connection is not permitted

You have the possibility to couple individual coil units with the same width and the same force constants. The total force is determined by adding the forces of the coupled coil units. The motors are connected in parallel to the servo drive, which leads to higher sum currents. In coupled operation , maintain special distances between coil units and the dependent wiring.