SP140 MC

Mechanical data

1-stage

  • Ratio

3

4

5

7

8

10

  • Efficiency under full load ŋ [%]

98.5

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 59

  • Service life Lh [h]

> 30000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

17.2

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • K = 38 mm

14.90

12.10

11

10.10

9.51

  • M = 48 mm

29.50

26.70

25.60

24.70

24.20

Torques and speeds

  • Rated torque at the output T2N [Nm]
  • at n1N

127

195

182

187

186

195

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

310

480

380

  • EMERGENCY STOP torque T2Emer [Nm]
  • Possible 1000 times during the service life of the gear unit

1250

1350

1250

  • Nominal input speed n1N [min-1]

3000

3500

4500

  • Maximum input speed n1Max [min-1]

6000

  • Idle torque T012 [Nm]
  • Based on the drive

4.10

3.50

2.80

2.20

1.80

1.70

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 4 / Reduced ≤ 2

  • Maximum torsional rigidity Ct21 [arcmin]

53

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

9870

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

9900

  • Maximum breakdown torque M2Max [Nm]

952

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing discs

Mechanical data

2-stage

  • Ratio

16

20

25

28

32

35

40

50

64

70

100

  • Efficiency under full load ŋ [%]

96.5

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 59

  • Service life Lh [h]

> 30000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

17

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • G = 24 mm

3.19

2.71

2.67

2.34

1.65

2.32

2.10

2.08

2.07

  • K = 38 mm

10.30

9.77

9.73

9.41

2.34

9.39

9.16

9.15

1.39

9.14

Torques and speeds

  • Rated torque at the output T2N [Nm]
  • at n1N

277

297

298

328

287

329

364

367

304

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

480

380

480

380

  • EMERGENCY STOP torque T2Emer [Nm]
  • Possible 1000 times during the service life of the gear unit

1350

1250

1350

1250

  • Nominal input speed n1N [min-1]

4500

  • Maximum input speed n1Max [min-1]

6000

  • Idle torque T012 [Nm]
  • Based on the drive

1.10

1

0.96

0.80

0.72

0.60

0.55

0.45

0.40

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 6 / Reduced ≤ 4

  • Maximum torsional rigidity Ct21 [arcmin]

53

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

9870

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

9900

  • Maximum breakdown torque M2Max [Nm]

952

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing discs