Installation position
Notice | |
Damage to the electric cylinder due to ingress of liquids In the vertical installation position IM V3, liquids or foreign bodies can enter the electric cylinder via the spindle drive.
|
Notice | |
Contamination due to leakage of liquids and lubricants In the vertical installation position IM V1, liquids or lubricants can escape from the electric cylinder via the spindle drive.
|
The standard installation position of the electric cylinders is the design IM B5 and IM V1 according to DIN EN 60034-7.
| |
Risk of injury due to unsecured axes The ball screw has no self-locking feature and can therefore extend or retract unintentionally when de-energized. Vertical axes must always be additionally secured.
|
The built-in holding brake [+] is not suitable for service braking, as there is no monitoring for wear and functionality by the servo drive and the configuration. This applies in particular to vertical axes.
Notice | |
Safety measures for vertical axes must be applied When operating vertical axes, appropriate additional measures must be taken; for example, including but not only:
|