Mechanical and electrical requirements

►Use the identification plate and the type code table to check whether the electric cylinder used is equipped with an integrated anti-twist protection [+] and/or a holding brake [+].
Mechanical and electrical requirements 1:

With integrated anti-twist protection [+], the end positions are provided by the electronic identification plate. Note the different start-up depending on the version of the anti-twist protection.

►Check travel path of the electric cylinder and remove blockages
►Check drive for damage
►Check mounting and alignment
►Tighten screw connections correctly
►Install mechanical, thermal and electrical protection devices, consider additional fuses according to Installation position
►Ensure wiring, connection and proper grounding for electric cylinder and servo drive