Size AA3053
Electrical data
AA3053 | -14yz | -34yz | -44yz | -54yz | -64yz |
|---|---|---|---|---|---|
Maximum nominal supply voltage Un [V AC] | 480 | 480 | 480 | 480 | 480 |
Peak current Imax [A] | 18.4 | 36.8 | 36.8 | 36.8 | 36.8 |
Continuous current I0 [A] | 7.4 | 7.4 | 7.4 | 7.4 | 7.4 |
Nominal output Pn [kW] | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 |
Force constant Kf [N/A] | 1689 | 844 | 844 | 422 | 422 |
Voltage constant kE [Vrms/kmin-1] | 115 | 115 | 115 | 115 | 115 |
Winding resistance R20 [Ω] | 2.45 | 2.45 | 2.45 | 2.45 | 2.45 |
Winding inductance L [mH] | 11.1 | 11.1 | 11.1 | 11.1 | 11.1 |
Mechanical data
AA3053 | -14yz | -34yz | -44yz | -54yz | -64yz |
|---|---|---|---|---|---|
Peak force Fmax [N] | 25000 | 25000 | 25000 | 12500 | 12500 |
Continuous force F0 [N] | 12466 | 6233 | 6233 | 3166 | 3166 |
Maximum acceleration amax [m/s2] | 10 | 20 | 20 | 40 | 40 |
Maximum velocity vmax [m/s] | 0.25 | 0.5 | 0.5 | 1.0 | 1.0 |
Overall length [mm] | 475 | 475 | 475 | 475 | 475 |
Maximum travel, stroke [mm] | 250 | 250 | 250 | 250 | 250 |
Dynamic load rating Cdvn [kN] | 33 | 55 | 55 | 23 | 23 |
Static load rating C [kN] | 120 | 141 | 141 | 52 | 52 |
Lead p [mm] | 5 | 10 | 10 | 20 | 20 |
integrated anti-twist protection | – | – | yes | – | yes |
Spindle diameter [mm] | 32 | 32 | 32 | 32 | 32 |
Positioning clearance [mm] | ±0.020 | ±0.015 | ±0.015 | ±0.015 | ±0.015 |
Positioning with backlash [mm] | – | – | ±0.025 | – | ±0.035 |
Rotor moment of inertia J [kgcm2] | 26.4 | 26.4 | 26.4 | 26.4 | 26.4 |
Rotor moment of inertia with | 29.7 | 29.7 | 29.7 | 29.7 | 29.7 |
Weight [kg] | 20.0 | 20.0 | 20.0 | 20.0 | 20.0 |
Weight with holding brake [+] mbr [kg] | 21.0 | 21.0 | 21.0 | 21.0 | 21.0 |
Compatibility with ISO 15552 for pneumatic cylinders
AA3053 | -14yz | -34yz | -44yz | -54yz | -64yz |
|---|---|---|---|---|---|
corresponds to pneumatic cylinder size with piston diameter [mm] | Ø 100 | Ø 100 | Ø 100 | Ø 100 | Ø 100 |
Dimensions flange [mm] | 110 x 110 | 110 x 110 | 110 x 110 | 110 x 110 | 110 x 110 |
Drilling pattern threaded holes for | 89 x 89 | 89 x 89 | 89 x 89 | 89 x 89 | 89 x 89 |
Thread dimension spindle end | M20 x 1.5 | M20 x 1.5 | M20 x 1.5 | M20 x 1.5 | M20 x 1.5 |
Holding brake performance data [+]
AA3053 | -14yz | -34yz | -44yz | -54yz | -64yz |
|---|---|---|---|---|---|
Holding force at 120°C Fbr120 [N] | 16336 | 8168 | 8168 | 4084 | 4084 |
Supply voltage Ubr [V DC] | 24 | 24 | 24 | 24 | 24 |
Electrical power Pbr [W] | 24 | 24 | 24 | 24 | 24 |
Current at 20°C Ion [A] | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Current at 120°C Ion [A] | 0.71 | 0.71 | 0.71 | 0.71 | 0.71 |
Release delay time tbrh [ms] | 90 | 90 | 90 | 90 | 90 |
Application delay time tbrl [ms] | 30 | 30 | 30 | 30 | 30 |