StopWatchdog

Stops a watchdog and provide runtime information.

Syntax

Definition:

HRESULT StopWatchdog(
    HRESULT   hrStartWatchdog,
    ULONGLONG& nFunctionsMonitored,
    ULONG&    nFractionProcessed,
    LONG&     tRest
)

Parameters

Name

Type

Description

hrStartWatchdog

HRESULT

HRESULT indicating the result of the function used to start the watchdog (If SUCCEEDED(hrStartWatchdog) equals false, no operation is executed.)

nFunctionsMonitored

ULONGLONG&

Returns the number of functions monitored

nFractionProcessed

ULONG&

Returns the fraction processed accumulated over the monitored functions in percent

tRest

LONG&

Returns the remaining computation time in us (may be negative)

StopWatchdog 1: Return value

HRESULT

Required License

TC3 Vision Base

System Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT V3.1. 4024.44 or later

PC or CX (x64) with PL50, e.g. Intel 4-core Atom CPU

Tc3_Vision