S-0-0301 Allocation of real-time control bit 1
Bits 6 and 7 of S-0-0134 are used to define two real-time control bits. They can be updated by the master during each communication cycle. This parameter assigns an IDN to real-time control bit 1 (bit 6 of S-0-0134). In all instances bit 0 of the selected parameter is transferred.
Attributes
| 
 Name  | 
 Value  | 
|---|---|
| 
 Datatype  | 
 idn  | 
| 
 Data length in bit  | 
 16  | 
| 
 Decimal point  | 
 0  | 
| 
 Min value  | 
 -  | 
| 
 Default  | 
 0  | 
| 
 Max value  | 
 -  | 
| 
 Unit  | 
 -  | 
| 
 Changeable in EtherCAT state  | 
 PreOp  | 
| 
 Cyclic transfer  | 
 No  | 
| 
 Device parameter  | 
 No  | 
| 
 Related to interface revision  | 
 No  | 
All IDNs that can be changed in OP can be cyclically assigned to the real-time control bits.
![]()  | Nested structure Note the nesting depth and the structure information at the start of the descriptions.  | 
![]()  | For further information please look into the involved IDN:  | 