Diagmessages für AMP8000/AMP8500




Objektbeschreibung




Diagmessages für Versorgungs- und Verteilermodule





Standard-Messages






0000, No errors






2310, Continuous overcurrent. Output: UU.






2380, Continuous overcurrent (total DC link out current)






2381, Continuous overcurrent. Output: UU. Reaction: Generative brake order






2382, Continuous overcurrent (total DC link out current). Reaction: Generative brake order






2383, Continuous overcurrent. Output: UU. Reaction: Torque off






2385, Peak overcurrent. Output: UU






2386, Peak overcurrent (total DC link out current)






2387, Short circuit. Output: UU






2388, Short circuit (total DC link out current)






23A0, Continuous overcurrent. Output: UU






23A1, Continuous overcurrent (total DC link out current)






3110, Mains overvoltage






3130, Mains phase failure






3180, Mains voltage higher than brake resistor operating voltage






3181, Mains phase failure. Reaction: Generative brake order






3182, Wrong mains type






31A0, Mains overvoltage






31A1, Mains undervoltage






3210, DC link overvoltage






3220, DC link undervoltage






3281, DC link overvoltage with Torque off






3282, DC link undervoltage with Torque off






3283, DC link timeout at state UU






32A0, DC link undervoltage






4210, Excess temperature device: SS






4280, Excess temperature device: SS. Reaction: Generative brake order






42A0, Excess temperature device: SS






5180, 24 V supply overcurrent: SS






5183, 24 V dcdc supply, first stage: SS






5187, 24V dcdc supply, second stage: SS






518A, 24 V supply out of range: SS






51A0, 24 V supply overcurrent: SS






5560, Read data failed: SS






5561, Missing data: SS






556C, Write data failed: SS






5570, Reset data failed: SS






5590, SS EEPROM device address is incompatible with this firmware






5592, SS Firmware index is incompatible with this firmware






5593, SS Structure version is incompatible with this firmware






5595, SS Component type is incompatible with this firmware






5596, Product is incompatible with this firmware






5598, BIC update failed: SS






55D0, Restored error messages from persistent memory






6010, Software reset (watchdog)






6081, Watchdog exceeded (Id: UU)






6310, Loss of parameters






6320, Parameter error






7111, Brake chopper failure






7112, Brake chopper overcurrent






7180, Brake resistor not found






7183, Brake resistor overloaded






71A0, Brake resistor overloaded






7580, I2C communication failure SS






7581, Data collector not running






7582, Data collector SS version is incompatible with this firmware






7584, Data collector communication failed: SS






7585, Data collector update failed: SS






75A0, Data collector communication failed: SS






87D0, PLL sync lost






FF1D, Charge resistor overloaded with error reaction torque off






FF1E, Fan malfunction






FF1F, Fan malfunction. Reaction: Generative brake order






FFA0, Fan malfunction






FFC0, SS executed successfully




Objektbeschreibung für Versorgungs- und Verteilermodule



AMI8100 | Kompakte integrierte Servoantriebe



ASI8100 | Kompakte integrierte Schrittmotorantriebe


Rotatorische Servomotoren


Translatorische Servomotoren


Planetengetriebe


XTS | Linearer Produkttransport


XPlanar | Planarmotorantriebssystem


Kompakte Antriebstechnik


Zubehör


Software


Archiv

TwinCAT 3

TwinCAT 2

MX-System

Branchenlösungen

Allgemeine Produktinformationen

Suche

News

Home