ZB8610

Number of channels

1 fan

Nominal voltage

24 V DC (-15 %/+20 %)

Current consumption
(at 24 V operating voltage)

ca. 45 mA

Operating modes

temperature-controlled, full speed, frequency-controlled

Rotational frequency fan

adjustable in 9 steps via frequency (1…9 Hz), max. ~5,500 rpm

Diagnostics,
max. output current

fan fault,
15 mA

Life span

MTBF typ. = 280,000 h @ 20 °C

Special features

increased performance and extended temperature range for various terminals

Dimensions (W x H x D)

47 mm x 20 mm x 55 mm

Weight

aprox.32 g (incl. bracket)

Operating/storage temperature

-25…+70 °C/-40…+85 °C

Relative humidity

95 %, no condensation

Vibration/shock resistance

conforms to EN 60068-2-6/EN 60068-2-27

EMC immunity/emission

conforms to EN 61000-6-2/EN 61000-6-4

Protect. class/installation pos.

IP 20/see chapter “Mounting/Demounting”

Approvals/Markings*)

CE, EAC, UKCA
cULus