Scanning I/O Devices

Scanning I/O Devices 1:
Ensure that TwinCAT is in Config Mode
If required, click on the button Restart TwinCAT (Config Mode) to activate the Config Mode
Scanning I/O Devices 2:
Expand Solution Explorer > TwinCAT Project > I/O
Right-click on Devices to open the context menu
Click Scan in the context menu
Scanning I/O Devices 3:

The dialog box TcXaeShell opens.

Confirm with OK



Depending on the components of your XTS system, there are different devices to choose from:

Beckhoff recommends naming the devices clearly for a better overview.

Scanning I/O Devices 4:

The dialog box 8 new I/O devices found opens.

Activate the checkboxes of the devices that are to be selected for the current configuration
Confirm with OK
Scanning I/O Devices 5:

The dialog box TcXaeShell opens.

Confirm with Yes