Check tracks

You can click on the tracks in the menu in the left-hand column to obtain more detailed information.

Check tracks 1:
►Click on a track

The following information is displayed under Details:

The selected track is displayed with a green line in the XTS System View.

Set properties

Notice

Avoid damage to the product and functional errors

Be sure to correctly specify whether you are configuring a closed XTS system or an XTS system with defined endpoints.

If the specification is incorrect, the movers may leave the XTS system if the XTS system is open. In the case of a closed XTS system with incorrect specification, the movers cannot travel in a circle as usual.

Check tracks 2:
►Activate the checkbox Is closed so that the movers can move around the start/end position of the track

OR

►Deactivate the checkbox Is closed


For systems without Track Management or systems with only one track, the checkbox Is included in detection must always be activated.

Check tracks 3:
►Activate the checkbox Is included in detection so that all movers are detected by a module that belongs to the part of this track

OR

►Deactivate the checkbox Is included in detection