Settings of the trigger set
- ►If required, enter a name for the trigger set in the input field Name
- ►Enter a threshold value in the input field Threshold
- ►Select a parameter in the drop-down menu Data for which the scope is to be recorded
- ►Select And in the drop-down menu Combine if the conditions of all ANDed trigger sets are to be fulfilled
Only selected parameters available All previously selected parameters are listed in the drop-down menu Data. |
OR
- ►Select Or from the drop-down menu Combine if it is sufficient to fulfill the condition of a trigger set
ANDed links are treated before ORed links.
- ►Select the trigger for the action in the drop-down menu Release
The following triggers are possible:
RisingEdge
Rising edge through X.
FallingEdge
Falling edge through X.
OnChangeEnds
End of a change.
TimeInterval
Time interval after which the Trigger Set is triggered.
- ►Click on the button Go To Next Step to continue