Teaching file update

An already saved teaching that was created with an older software version can be used by the latest software version.

Teaching file update 1:
►Expand Solution Explorer > TwinCAT Project > SYSTEM > TcCOM Objects
►Double click on XtsProcessingUnit
Teaching file update 2:
►In the project window click on the Parameter (Online) tab
►Expand Teaching
►Check the online status of the parameter IsTeachingFileFormatUpToDate

If the online status of the parameter IsTeachingFileFormatUp­To­Date indicates FALSE:

Teaching file update 3:
►Click the Parameter (Init) tab in the project window
►Expand Teaching
►Right-click in the input field TriggerTeachingFileFormatUpdate to open the context menu
►In the context menu click Download
Teaching file update 4:

If the download was successful, the parameters IsTeachingValid and IsTeachingFileFormateUpToDate indicate TRUE.

If the download was unsuccessful, the parameters IsTeachingValid and IsTeachingFileFormateUpToDate indicate FALSE and an error message is displayed in the Error List message window.