Isolating cores
The number of available cores depends on the IPC used. Most systems have 4 or 12 cores, but 8 or 64 cores are also possible. Each core used for the XTS system must be isolated. At least one core must not be isolated in order to be able to use it for Windows. For more information on the distribution of cores, please contact the product specialist responsible for your region.
![]() | XTS Configurator must be closed Isolating cores is only possible if the XTS Configurator is closed. |
- ►Expand Solution Explorer > TwinCAT Project > SYSTEM
- ►Double-click on Real-Time
- ►Click on Read from Target to call up the distribution of the cores
- ►Click on Set on Target to change the distribution of the cores
Notice | |
Saving and closing other applications As the IPC is automatically restarted after entering the cores to be isolated, save and close all other applications that are open on the IPC. |
The dialog box Change number of shared cores opens.
- ►Enter the number of isolated cores using the arrow keys
OR
- ►Enter the number of isolated cores in the input field Available (Shared/Isolated)
- ►Confirm with Set
The IPC restarts automatically.