Initialization
The function block FB_TcIoXtsEnvironment must be configured once for the XTS project so that all parameters of the Processing Unit can be accessed. If XTS objects are to be used in the project, the function block FB_XtsEnvironment must also be configured.
The function blocks for accessing the parameters of the InfoServer and CA group are integrated in the Tc3 XTS Utility. You must activate the function blocks for initialization so that the function blocks can be used in the further course via the FB_TcIo-XtsEnvironment.
The function block FB_TcIoXtsEnvironment must be initialized once when starting or during an online change in order to obtain information about all objects. After initialization all parameters are available via FB_TcIoXtsEnvironment. All parameters can be accessed by calling the corresponding methods. There is no automatic cyclic update of the data.