Method – parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

GetRailLength

Geometry

LREAL

–

Returns the length of the guide rails.

GetRailsRing

Geometry

BOOL

–

Returns that the guide rails are closed.

SetRailLength

Geometry

BOOL

LREAL

Sets the length of the guide rails.

SetRailsRing

Geometry

BOOL

BOOL

Sets that the guide rails are closed.

GetDefaultGapControlMode

Gap Control

MC_DEFAULT_GAP_CONTROL_MODE

–

Returns the gap control mode.

GetGapControlDirection

Gap Control

MC_GAP_CONTROL_DIRECTION

–

Returns the direction of the gap control.

GetStandbyGapControl

Gap Control

BOOL

–

Returns the standby state of the gap control.

GetDefaultGap

Gap Control

LREAL

–

Returns the default value of the gap.

GetDefaultVelocity

Gap Control

LREAL

–

Returns the default velocity of the gap control.

GetDefaultAcceleration

Gap Control

LREAL

–

Returns the default acceleration of the gap control.

GetDefaultDeceleration

Gap Control

LREAL

–

Returns the default deceleration of the gap control.

GetDefaultJerk

Gap Control

LREAL

–

Returns the default jerk of the gap control.

SetDefaultGapControlMode

Gap Control

BOOL

MC_DEFAULT_GAP_CONTROL_MODE

Sets the gap control mode.

SetGapControlDirection

Gap Control

BOOL

MC_GAP_CONTROL_DIREKTION

Sets the direction of the gap control.

SetStandbyGapControl

Gap Control

BOOL

BOOL

Sets the standby state of gap control.

SetDefaultGap

Gap Control

BOOL

LREAL

Sets the default value of the gap.

SetDefaultVelocity

Gap Control

BOOL

LREAL

Sets the default velocity of the gap control.

SetDefaultAcceleration

Gap Control

BOOL

LREAL

Sets the default acceleration of the gap control.

SetDefaultDeceleration

Gap Control

BOOL

LREAL

Sets the default deceleration of the gap control.

SetDefaultJerk

Gap Control

BOOL

LREAL

Sets the default jerk of the gap control.