Method – parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

GetVelocityLoopType

General

TcSdVelocityLoop­Type

–

Returns the control mode of the velocity control.

GetKp

General

LREAL

–

Returns the proportional gain of the velocity control.

GetKpStandstill

General

LREAL

–

Returns the proportional gain of the velocity control at standstill.

GetKpArea

General

LREAL

–

Returns the proportional gain of the velocity control in the area.

GetKpAreaStandstill

General

LREAL

–

Returns the proportional gain of the velocity control in the area at standstill.

GetTn

General

LREAL

–

Returns the integer time constant of the velocity control.

GetTnStandstill

General

LREAL

–

Returns the integer time constant of the velocity control at standstill.

GetTnArea

General

LREAL

–

Returns the integer time constant of the velocity control in the area.

GetTnAreaStandstill

General

LREAL

–

Returns the integer time constant of the velocity control in the area at standstill

SetVelocityLoopType

General

BOOL

TcSdVelocityLoopType

Sets the control mode of the velocity control loop.

SetKp

General

BOOL

LREAL

Sets the proportional gain of the velocity control.

SetKpStandstill

General

BOOL

LREAL

Sets the proportional gain of the velocity control at standstill.

SetKpArea

General

BOOL

LREAL

Sets the proportional gain of the velocity control in the area.

SetKpAreaStandstill

General

BOOL

LREAL

Sets the proportional gain of the velocity control in the area at standstill.

SetTn

General

BOOL

LREAL

Sets the integer time constant of velocity control.

SetTnStandstill

General

BOOL

LREAL

Sets the integer time constant of the velocity control at standstill.

SetTnArea

General

BOOL

LREAL

Sets the integer time constant of the velocity control in the area.

SetTnAreaStandstill

General

BOOL

LREAL

Sets the integer time constant of the velocity control in the area at standstill.

GetMaxVelocity

Advanced

LREAL

–

Returns the setting for the maximum velocity.

SetMaxVelocity

Advanced

BOOL

LREAL

Sets the maximum velocity.