Method – parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

GetPositionLoopType

General

TcSdPositionLoop­Type

–

Returns the control mode of the control loop.

GetKp

General

LREAL

–

Returns the proportional gain of the position control.

GetKpStandstill

General

LREAL

–

Returns the proportional gain of the position control at standstill.

GetKpArea

General

LREAL

–

Returns the proportional gain of the position control in the area.

GetKpAreaStandstill

General

LREAL

–

Returns the proportional gain of the position control in the area at standstill.

SetpositionLoopType

General

BOOL

TcSdPositionLoopType

Sets the control mode of the control loop.

SetKp

General

BOOL

LREAL

Sets the proportional gain of the position control.

SetKpStandstill

General

BOOL

LREAL

Sets the proportional gain of the position control at standstill.

SetKpArea

General

BOOL

LREAL

Sets the proportional gain of the position control in the area.

SetKpAreaStandstill

General

BOOL

LREAL

Sets the proportional gain of the position control in the area at standstill.

GetPosLoopFilter

Advanced

LREAL

–

Returns the setting of the low-pass frequency of the position filter.

SetPosLoopFilter

Advanced

BOOL

LREAL

Sets the low-pass frequency of the position filter.