Method – parameter (Online)

Parameter

Group

Return Type

Input Type

Explanation

GetMoverId

MoverIdDetection

STRING(3)

–

Returns the ID of the mover.

GetAxisId

Info

UDINT

–

Returns the ID of the axis.

GetAxisObjectId

Info

OTCID

–

Returns the object ID of the axis.

GetDistanceDriven

Info

LREAL

–

Returns the value of the absolute travel distance.

Unit: mm

GetDistanceDrivenInKm

Info

LREAL

–

Returns the value of the absolute travel distance.

Unit: km

GetDriveAddress

Info

UINT

–

Returns the address of the module on which the mover is located.

GetDriveModuleNumber

Info

UDINT

–

Returns the number of the module on which the mover is located.

GetDriveTerminalOid

Info

OTCID

–

Returns the object ID of the module on which the mover is located.

GetEncoderAddress

Info

UINT

–

Returns the address of the encoder terminal on which the mover is located.

GetEncoderModuleNumber

Info

UDINT

–

Returns the number of the encoder terminal on which the mover is located.

GetEncoderTerminal­Oid

Info

OTCID

–

Returns the object ID of the encoder terminal on which the mover is located.

GetHasDriveError

Info

BOOL32

–

Returns the error state of the drive.

GetHasEncoderError

Info

BOOL32

–

Returns the error state of the encoder terminal.

GetMasterNetId

Info

AmsNetId

–

Returns the Net ID of the module.

GetPositionInfo

Info

REFERENCE TO ST_PositionInfo

–

Returns the position information of the part and the track

GetSoftdriveOid

Info

OTCID

–

Returns the object ID of the SoftDrive.