Method – parameter (Init)

Parameter

Group

Return Type

Input Type

Explanation

GetAdsPort

General

WORD

–

Returns the ADS port.

GetActiveTrackObjectId

General

OTCID

–

Returns the object ID of the active track.

GetTaskOid

General

OTCID

–

Returns the object ID of the task.

SetActiveTrackObjectId

General

BOOL

OTCID

Sets the active track by entering the object ID of the track.

GetIsActivated

General

BOOL

–

Returns the activated state of the mover.

SetIsActivated

General

BOOL

BOOL

Sets the activated state of the mover.

GetSimulatedStart­UpPart

Simulation

OTCID

–

Returns the object ID of the start part in the simulation.

GetSimulatedStart­UpPosition

Simulation

LREAL

–

Returns the position at startup.

GetSimulatedStart­UpId

Simulation

STRING(3)

–

Returns the ID of the mover.

SetSimulatedStart­UpPart

Simulation

BOOL

OTCID

Sets the start part by entering the object ID of the part.

SetSimulatedStart­UpPosition

Simulation

BOOL

LREAL

Sets the start position.

SetSimulatedStart­UpId

Simulation

BOOL

STRING(3)

Sets the ID of the mover.