Method - parameter (Online)
| Parameter | Group | Return Type | Input Type | Explanation | 
|---|---|---|---|---|
| GetAngle | Info | LREAL | – | Returns the angle of the module in degrees. | 
| GetGlobalNumber | Info | UDINT | – | Returns the global number of the module. The global number is used to distinguish all modules managed by the Processing Unit. | 
| GetLength | Info | LREAL | – | Returns the length of the module in mm. | 
| GetMasterNetId | Info | AMSNETID | – | Updates the Net ID of the EtherCAT master. | 
| GetDriveAddress | DriveInfo | UINT | – | Returns the address of the drive terminal. | 
| GetDriveConfigIdentity | DriveInfo | ST_DriveConfigIdentity | – | Returns the structure of the configured drive identity with the vendor ID, the code, the revision and the serial number. | 
| GetDriveOnlineIdentity | DriveInfo | ST_DriveOnlineIdentity | – | Returns the structure of the online drive identity with vendor ID, the code, the revision and the serial number. | 
| GetDriveState | DriveInfo | DriveState | – | Returns the state of the drive terminal. | 
| GetEncoderAddress | EncoderInfo | UINT | – | Returns the address of the encoder terminal. | 
| GetEncoderConfigIdentity | EncoderInfo | ST_EncoderConfigIdentity | – | Returns the structure of the configured encoder identity with the vendor ID, the code, the revision and the serial number. | 
| GetEncoderOnlineIdentity | EncoderInfo | ST_EncoderOnlineIdentity | – | Returns the structure of the online encoder identity with vendor ID, the code, the revision and the serial number. | 
| GetEncoderSensorValues | EncoderInfo | ARRAY[1..32] OF ST_EncoderSensorValues | – | Returns the values of the encoder sensor. | 
| GetDriveBTN | General | BTN | – | Returns the Beckhoff Traceability Number (BTN). | 
| GetDriveDeviceName | General | STRING(15) | – | Returns the device name. | 
| GetDriveDeviceType | General | UDINT | – | Returns the device type. | 
| GetDriveHardwareVersion | General | STRING(15) | – | Returns the hardware version. | 
| GetDriveSoftwareVersion | General | STRING(15) | – | Returns the software version. | 
| GetI2TWarnLevel | AmplifierSettings | USINT | – | Returns the I2T warning level. | 
| GetI2TErrorLevel | AmplifierSettings | USINT | – | Returns the I2T error level. | 
| GetTemperatureWarnLevel | AmplifierSettings | UINT | – | Returns the temperature warning level. | 
| GetTemperatureErrorLevel | AmplifierSettings | UINT | – | Returns the temperature error level. | 
| GetMaxDcLinkVoltage | AmplifierSettings | UDINT | – | Returns the maximum of the DC link voltage. | 
| GetMinDcLinkVoltage | AmplifierSettings | UDINT | – | Returns the minimum of the DC link voltage | 
| GetEnabledBrakeChopper | AmplifierSettings | BOOL | – | Returns the settings of the brake chopper. | 
| GetBreakAfterBridgeDisable | AmplifierSettings | BOOL | – | Returns the setting of the interruption after disabling the data transmission. | 
| GetI2TTemperatures | I2T | REFERENCE TO ARRAY [1..15] OF REAL | – | Returns the I2T value. | 
| GetAuxiliaryVoltage5V | InfoData | REAL | – | Returns the operating voltage of 5 V. | 
| GetAuxiliaryVoltage10V | InfoData | REAL | – | Returns the operating voltage of 10 V. | 
| GetAuxiliaryVoltage24V | InfoData | REAL | – | Returns the operating voltage of 24 V. | 
| GetDCLinkVoltage | InfoData | REAL | – | Returns the DC link voltage. | 
| GetCurrentScaling | InfoData | REAL | – | Returns the scaling of the current intensity. | 
| GetChipID | InfoData | ULINT | – | Returns the chip ID. | 
| GetDeviceInfo | InfoData | UDINT | – | Returns the device information. | 
| GetMaxDCLinkVoltageLast500ms | InfoData | REAL | – | Returns the maximum DC link voltage of the last 500 ms. | 
| GetMaxOverallCurrentLast500ms | InfoData | REAL | – | Returns the overall current of the last 500 ms | 
| GetOverallCurrent | InfoData | REAL | – | Returns the overall current. | 
| GetPCBTemperatures | InfoData | REFERNCE TO ARRAY [1..4] OF REAL | – | Returns the temperature of PCB. | 
| GetCode | VendorData | ULINT | – | Returns the code. | 
| GetCoilOvercurrentThreshold | VendorData | UDINT | – | Returns the overcurrent threshold of the coil. | 
| GetCoilPeakCurrent | VendorData | UDINT | – | Returns the current peaks of the coil. | 
| GetCoilRatedCurrent | VendorData | UDINT | – | Returns the nominal current of the coil. | 
| GetCoilThermalTimeConstant | VendorData | UINT | – | Returns the thermal time constant of the coil. | 
| GetEnableOverallCurrentPeakDetection | VendorData | BOOL | – | Returns the setting of the peak current detection. | 
| GetEnableOverallNegativeCurrentChangeError | VendorData | BOOL | – | Returns the setting of the error for the negative overall current change. | 
| GetEnableOverallNegativepowerError | VendorData | BOOL | – | Returns the setting of the overall negative error. | 
| GetOverallCurrentFilter | VendorData | UINT | – | Returns the overall current filter. | 
| GetOverallCurrentGain | VendorData | UINT | – | Returns the gain of the overall current. | 
| GetOverallCurrentOffset | VendorData | DINT | – | Returns the offset of the overall current. | 
| GetOverallOvercurrentThreshold | VendorData | UDINT | – | Returns the overall overcurrent threshold. | 
| GetPolarity | VendorData | UDINT | – | Returns the polarity. |