Define parameters
For each track you need to set the three most important parameters:
Notice | |
Avoid damage to the product and functional errors Be sure to correctly specify whether you are configuring a closed XTS system or an XTS system with defined endpoints. If the specification is incorrect, the movers may leave the XTS system if the XTS system is open. In the case of a closed XTS system with incorrect specification, the movers cannot travel in a circle as usual. |
- ►Activate the checkbox Is closed if the XTS system is closed
OR
- ►Deactivate the checkbox Is closed if the XTS system is open
- ►Activate the checkbox Is included in detection if the XTS system is closed or only has one track
OR
- ►Deactivate the checkbox Is included in detection if the XTS system is open or has multiple tracks
![]() | If the XTS system contains tracks that share parts, you must define which tracks perform the detection. It is important that each part within a Processing Unit only occurs once in the detection process, otherwise too many movers may be displayed and the startup of the XTS system may be prevented. |
Add Parts
Select the order of the parts according to their appearance in the XTS system. Make sure that the parts form a continuous line on which the movers can move.
- ►Click + button to add an XTS Part
- ►In the drop-down menu XTS Part select the Part to be added to the current track
