XTS sensor channel
A sensor channel must be added to each module.
![]() | Example sensor channel for module with feed The addition of a sensor channel is shown with an AT0250-5250 as an example. It belongs to an AT2001-0250 module with feed. |
- ►Expand Solution Explorer > TwinCAT Project > I/O > Devices > Device (EtherCAT)
- ►Right-click on Term (AT2001-0250) to open the context menu
- ►Click Add New Item... in the context menu
The Insert Device dialog box opens.
- ►Expand Beckhoff Automation GmbH & Co. KG > XTS
- ►Select AT2001-5250 Sensor line with feed
- ►If required, enter a name for the sensor channel in the input field Name
- ►Confirm with Ok
A Term (AT2001-5250) is added to the module Term (AT2001-0250).
After the sensor channel has been added to the module with feed, all further modules of the infeed line can be added to the EtherCAT master.
- ►Add all further modules of the infeed line with a corresponding sensor channel in the same way