Parameter (Online)

Parameter

Group

Type

PTCID

Explanation

AreAllPositionsValid

MoverDetection

BOOL

0x03080256

Returns TRUE if all mover positions are valid.

DetectionCycleCount

MoverDetection

UDINT

0x03080259

Returns the number of detection cycles.

DetectedMoverCount

MoverDetection

UDINT

0x03080257

Returns the number of detected movers during the latest detection cycle.

ExpectedMoverCount

MoverDetection

UDINT

0x03080258

Returns the number of expected movers - equal to the number of created mover objects.

ScannedModuleCount

MoverDetection

UDINT

0x03080225

Returns the number of modules which are scanned during one detection cycle.

MoverPositions

MoverDetection

–

0x0308020D

Returns an array containing the actual positions of all movers.

HasIdDetectionError

MoverIdDetection

BOOL

0x03080252

Returns TRUE if the mover ID detection has failed.

IsIdDetectionValid

MoverIdDetection

BOOL

0x03080251

Returns TRUE if the mover IDs are detected.

IsIdDetectionActive

MoverIdDetection

BOOL

0x03080268

Returns TRUE if the mover ID detection is running.

MoverIds

MoverIdDetection

–

0x0308027C

Returns an array containing the IDs of all movers.

IsTeachingChanged

Teaching

BOOL

0x0308022B

Returns TRUE if a teaching has been performed during the driver is running.

IsTeachingValid

Teaching

BOOL

0x03080255

Returns TRUE if the teaching is valid.

IsTeachingFileFormatUpToDate

Teaching

BOOL

0x03080290

Returns TRUE if the teaching file uses the latest format definition.

HasInputCheckError

Diagnostics

BOOL

0x0308028F

Returns the result of the inputs check.

DriveState

Info

DriveState

0x000000A0

Returns the state of the drive system.

PartOrigins

Info

–

0x03080261

Returns an array containing all the origin transforms of the parts.

VersionString

Info

STRING(31)

0x03080287

Returns the version string of the driver.

MoverCount

Structure

UDINT

0x0308020A

Returns the number of movers.

MoverObjectIDs

Structure

–

0x0308020B

Returns an array containing the object IDs of all movers.

PartCount

Structure

UDINT

0x03080203

Returns the number of parts.

PartObjectIDs

Structure

–

0x03080224

Returns an array containing the object IDs of all parts.

TaskCount

Structure

UDINT

0x0000009C

Returns the number of tasks.

TaskObjectIDs

Structure

–

0x0000009D

Returns an array with the task object IDs.

TrackCount

Structure

UDINT

0x0308020E

Returns the number of tracks.

TrackObjectsIDs

Structure

–

0x0308020F

Returns an array containing the object IDs of all tracks.