Parameter (Init)

Parameter

Group

Type

PTCID

Explanation

OperationMode

General

OperationMode

0x0308022C

Choose between 'Normal' to work with actual hardware and 'Simulation' to work in simulation.

For more information, see OperationMode.

MoverType

Mover

MoverType

0x00000090

Choose the appropriate mover type. Use custom for a non Beckhoff mover.

For more information, see MoverType.

MagnetPlateType

Mover

MagnetPlateType

0x00000091

Selection of the magnetic plate set.

Attention! Choose the correct magnet plate type. If not correct the mover can jump unexpectedly.

For more information, see MagnetPlateType.

MoverSortOrder

Mover

SetOrderEnum

0x00000048

Choose the sort order of the movers.

For more information, see MoverSortOrder.

MinMechanicalMover­Distance

Mover

LREAL

0x0308027A

Gets/sets the minimum position distance between the movers, which has to be measured in the curve. As a default the distance belonging to the mover type is used.

IdDetectionMode

MoverIdDetection

MoverIdDetection­Mode

0x03080246

Choose the ID detection mode to enable Mover 1 detection.

For more information, see IdDetectionMode.

MoverPosition­Assign­ment

MoverIdDetection

MoverPosition­Assignment

0x03080253

Defines the lowest/highest position

For more information, see MoverPositionAssignment.

Parameter

Group

Type

PTCID

Explanation

ExpectedMoverIds

MoverIdDetection

–

0x03080267

Configure the expected mover IDs for ID detection mode MultipleMover 1.

For more information, see ExpectedMoverIds.

TriggerMoverIdDetection

MoverIdDetection

TriggerMoverIdDetection

0x03080250

Triggers the Mover ID detection.

Attention! The axes controller will be momentary enabled.

TeachingFileNumber

Teaching

UDINT

0x0308022A

The number is appended to the teaching file name - like 'TcIoXts.TeachingData.0.bootdata'.

For more information, see Enter the number of the teaching file.

StartStandStillTeaching

Teaching

–

0x03080228

On download the teaching is started on the specified modules and will be stopped automatically.

For more information, see StartStandStillTeaching.

StartMovementTeaching

Teaching

–

0x03080269

On download the teaching is started. Then move movers over every module.

For more information, see StartMovementTeaching.

StopMovementTeaching

Teaching

StopMovementTeaching

0x03080270

On download the teaching will be applied instantaneously.

IsAbortOnTeachingWarningsEnabled

Teaching

BOOL

0x00000057

If set to TRUE then a teaching warning causes that the driver does not start up.

For more information, see IsAbortOnTeachingWarningsEnabled.

IsTeachingCheckSumCheckEnabled

Teaching

BOOL

0x00000055

If set to TRUE then the specified check sum is used to validate that the correct teaching file is loaded and is not corrupt.

For more information, see IsTeachingCheckSumCheckEnabled.

Parameter

Group

Type

PTCID

Explanation

TeachingCheckSum

Teaching

–

0x00000054

Array of values of the teaching check sum. After a new teaching one can read (upload) the checksum from the driver.

For more information, see TeachingCheckSum.

TeachingWarningLevel

Teaching

TeachingWarningLevel

0x0308028C

Specifies how strict the values of the teaching are checked.

For more information, see TeachingWarningLevel.

1 means very strict and

3 is the lowest level.

TriggerTeachingFileFormatUpdate

Teaching

TriggerTeachingFileFormatUpdate

0x000000A9

Triggers the system to update the teaching file format of the given teaching file on changing back to config mode

(overwrites the old file).

IsAutoDumpWritingEnabled

Diagnostics

BOOL

0x00000049

If enabled then the driver writes dump files automatically in certain situations (at start up, in error cases).

For more information, see IsAutoDumpWritingEnabled.

IsInputCheckEnabled

Diagnostics

BOOL

0x03080283

Enables the plausibility check of all input channels on the system.

For more information, see IsInputCheckEnabled.

WriteDump

Diagnostics

WriteDump

0x00000044

If downloaded manually then the driver writes a dump file.

UsedEventLogger

Diagnostics

EventMessenger

0x000000A4

Specifies how events/messages are reported by the driver.

For more information, see UsedEventLogger.

EtherCatMasterSyncTaskObjectId

Advanced

OTCID

0x03080233

Set the object ID of the task which is responsible for triggering the EtherCAT master which is set to independent DC time.

Suggested when using the 16 port EtherCAT network card.

IsCycleTimeWarning­Suppressed

Advanced

BOOL

0x00000046

If enabled then the warning that the driver does not run at 250 us is disabled.

Parameter

Group

Type

PTCID

Explanation

IsMoverFrozenErrorActivated

Advanced

BOOL

0x00000097

If enabled then the mover position is observed -

if it does not change for a number of cycles then an error is issued.

For more information, see IsMoverFrozenErrorActivated.

IsPositionBasedError­Forwarding­Enabled

Advanced

BOOL

0x00000092

If enabled then a hardware error is forwarded based on the position to the movers which are located on the faulting modules.

For more information, see IsPositionBasedErrorForwardingEnabled.

Optimization

Advanced

OptimizationEnum

0x00000047

Optimizes the movers movement or positioning slightly. Standard is optimize positioning.

For more information, see Optimization.

TriggerRedetection

Advanced

TriggerRedetection

0x00000098

If downloaded then all movers will loose their position and a new detection is performed. The order of movers might change.

CalculateNormAmplitude

Advanced

BOOL

0x030802B1

If set to TRUE then the mover's amplitude will be normalized.

IsPositionNoiseEnabled

Simulation

BOOL

0x0308022F

If enabled then a random noise using the specified bandwidth is added to the mover positions.

IsRandomStartUp­Enabled

Simulation

BOOL

0x03080285

If enabled and mode UseOffsetAndDistance is active then the start-up positions of the movers are randomized using the specified bandwidth.

MoverDistance

Simulation

LREAL

0x0308022E

Gets/sets the distance between simulated movers at start-up.

PositionOffset

Simulation

LREAL

0x0308022D

Gets/sets the position where the first simulated mover should be detected.

PositionNoiseBandwidth

Simulation

LREAL

0x03080231

Gets/sets a bandwidth which describes how much a position should toggle.

RandomStartUpBandwidth

Simulation

LREAL

0x03080232

Gets/sets a bandwidth which is used to modify the start-up positions of the movers. It is additionally applied to the offset and distance.

Parameter

Group

Type

PTCID

Explanation

PositionStartUpSimulationMode

Simulation

PositionStartUpSimulationMode

0x03080230

Defines how the start-up positions for the movers should be generated.

For more information, see PositionStartUpSimulationMode.

MoverIdStartUpSimulationMode

Simulation

MoverIdStartUpSimulationMode

0x0308027D

Defines how the mover ID(s) are generated at start-up.

For more information, see MoverIdStartUpSimulationMode.

RandomInitMode

Simulation

RandomInitMode

0x0308027F

Defines the mode to initialize the random seed.

For more information, see RandomInitMode.

RandomInitSeed

Simulation

DINT

0x03080280

Gets/sets the seed which is used to generate random numbers used for the positions and IDs.