Parameter (Init)

Parameter (Init) 1:
Click the Parameter (Init) tab in the project window
Expand MoverIdDetection
Parameter (Init) 2:
If necessary, reduce the value for the minimum position change during Mover ID detection in the input field DetectionMinMovement to reduce the position change of the movers

OR

If necessary, increase the value for the minimum position change during Mover ID detection in the input field DetectionMinMovement to increase the position change of the movers
Parameter (Init) 3:
If necessary, reduce the value for the current change filter in the input field DetectionFilter to build up the current more slowly and make Mover ID detection smoother

OR

If necessary, increase the value for the current change filter in the input field DetectionFilter to build up the current more quickly and make Mover ID detection more jerkily
Parameter (Init) 4:
If necessary, change the DetectionCurrentRamp value for the ramp of the Mover ID detection current
Parameter (Init) 5:
If necessary, change the DetectionMaxCurrent value for the limit of the Mover ID detection current