XTS Hygienic

Electrical data

    • Control voltage [VDC]

24

    • Power supply [VDC]

48

    • Current consumption - power supply nominal current [A]

16

    • Power consumption control voltage module [W/m]

20

    • Maximum segment length per power supply module [m]

≤ 3

At a constant velocity [m/s]

2

4

    • Power consumption per mover,
      48 VDC [W]

90

180

At peak acceleration [m/s2] and
mass of 1 kg

10

50

    • Power consumption per mover,
      48 VDC [W]

90

400

Mechanical data

Mover

ATH9011-0075-0550

ATH9013-0075-0550

    • Length [mm]

75

75

    • Number of rollers

6

6

    • Weight without magnetic plate set [g]

830

550

    • Weight, assembled with magnetic plate set AT9001-0550 [g]

1,060

780

    • Weight of magnetic plate set ATH9001-0550 [g]

230

230

Modules

ATH20xx

00-0250

01-0250

50-0500

51-0500

    • Height [mm]

96

96

198

198

    • Depth [mm]

250

250

315

315

    • Weight without attachments [kg]

4.0

5.4

8

9.4

    • Width on the machine bed [mm]

34

34

34

34

    • Upper width on the motor / guide [mm]

22

22

22

22

Protection class

    • Closed system

IP65 / IP66 / IP69K

Material

    • Housing

Stainless steel 1.4404 AISI 316L, Ra < 0.8 µm

    • Seals

VMQ silicone

System properties

    • Maximum force at standstill [N]
    • Dependent on the air gap between stator and drive magnet

90

    • Force constant KF at standstill [N/A]

7.5

    • Maximum force at 2 m/s [N]

75

    • Velocity at 48 VDC [m/s]

4

    • Acceleration without payload [m/s2]

≥ 75

    • Nominal force F0 [N]

30

    • Winding resistance of a phase R20 [Ω]

0.78

    • Synchronization accuracy at 1.5 m/s within a straight module [mm]
    • Dependent on the mechanical rigidity and applied load on the mover

≤± 0.15

    • Absolute accuracy within a straight module [mm]
    • Can be exceeded in the case of high thermal warming of the module or lack of parallelism / orthogonality of the encoder magnet to the module

≤± 0.25

    • Unidirectional repeatability at standstill [mm]
    • Can be exceeded in the case of large temperature differences of the module

≤± 0.01