Guide rails, 180° curved segment
The guide rails must be prepared before they are mounted on the motor modules. Further information can be found in the chapter Guide rails.
- ►Insert the locating pins [1] into the guide rails
- ►Push the seals [2] onto the locating pins with the pre-cut edge facing downward
- ►Slide the guide rail [1] onto the curved segment [2] until it is approximately 30 mm away
- ►Guide the seal [1] from top to bottom around the curved segment [2]
- ►Press the seal into the groove between the curved segment and the guide rail [3] with your fingernail
- ►Route the seal around the curved segment on the other side of the system in the same way
- ►Press the seal [1] into the groove [2] between the guide rail and the straight motor modules with your fingernail
- ►To facilitate installation, lift or move the guide rail slightly
- ►Continue pressing the seal in up to the end of the guide rail
- ►Install the seal on the other side of the system in the same way
- ►Tighten the screws [1] of the guide rail until hand-tight to secure the seals [2] on both sides of the system
- ►Grease the seals [1] between the curved segment [2] and the guide rail [3] on both sides of the system with petrolatum
- ►Carefully slide the guide rail [1] onto the curved segment [2]
- ►Make sure that the seal remains in place
- ►Tighten the screw [1] with sealing ring in the center of the curved segment until hand-tight to press the guide rail fully against the curved segment
- ►Then tighten the additional screws [2] with sealing rings until hand-tight
- ►Loosen the secured screws [1] on the upper guide rail slightly to install the ends of the seals
- ►Install the second guide rail with seals in the same way
The ends of the seals overlap at the starting points.
- ►Cut diagonally through both ends [3] of the overlapping seals [1] and [2] with a cutting tool
- ►Cut the seal on the other side of the system to length in the same way
- ►Loosen the screws on the upper guide rail slightly to bond the seals
- ►Apply adhesive to one end [1]
- ►Press the end into the groove to bond the two ends together
- ►Remove any adhesive residue with a lint-free cloth
- ►Bond the seal on the other side of the system in the same way
- ►Tighten the screws on the upper guide rail until hand-tight again