Straight guide rails

Notice

Align the rails with the motor modules

The guide rails must be installed on the motor modules in a specific orientation. To do this, position the holes in the rails over the threaded holes in the motor modules.

If the alignment is incorrect, the screws will not align with the threaded holes in the motor modules and cannot be screwed in.

When installing the straight guide rails, ensure that the guide rails are correctly aligned and that the lock is in the correct position.

Alignment of the guide rails

Straight guide rails 1:

The guide rail [1] must be centered over the motor module. The side of the motor module with the LED status indicator [2] is used for orientation.

Position of the lock

Straight guide rails 2:

The guide rail [1] with the lock [2] must always be installed at the top of the system. The lock must be removed before installing the movers and replaced with the rail mounting aid [+]. Further information can be found in the chapter Installing the movers.

Straight guide rails 3:
►Insert the locating pins [1] into all straight motor modules [2] and both curved segments [3]
Straight guide rails 4:
►Insert the locating pins [1] into the guide rail [2]
►Slide the seal [3] onto the locating pins
Straight guide rails 5:
►Place the guide rail [1] straight down onto the locating pins
►Place the lock [2] straight down onto the locating pins
Straight guide rails 6:
►Tighten the screws with sealing rings [1], leaving only a minimal gap, to secure the guide rail and lock










►Install the lower guide rail in the same way and secure it to prevent it from falling out
►Make sure that the guide rail is correctly aligned
Straight guide rails 7:

Simple bonding of the seal ends

During assembly, the ends of the seals between the motor modules and the rails must be bonded. For easy and correct bonding, begin inserting the seals approximately at the center of a motor module and at the center of a straight guide rail.

Straight guide rails 8:

The seal between the motor modules and the rails must be installed so that the flat side [1] faces outward and the round side [2] faces inward.

►Make sure that all seals are installed flush with the system components
►Avoid pulling on the seals
Straight guide rails 9:
►Press the seal [1] into the groove between the motor module [2] and the straight guide rail [3] with your fingernail
►To facilitate installation, lift or move the guide rail slightly
►Continue pressing the seal in up to the end of the guide rail
Straight guide rails 10:
►Press the seal [1] into the groove [2] on the other side of the system in the same way
Straight guide rails 11:
►Tighten the screws [1] of the guide rail until hand-tight to secure the seals [2] on both sides of the system