Guide rails
Components | Interval | Maintenance |
|---|---|---|
Straight | Every month | Clean the running surfaces1) |
6 months | Check all connections for correct fastening and damage | |
6 months | Check that the guide rails are properly secured to the motor modules | |
Curved segments | If required | Apply a small quantity of lubricant2) to the running surfaces |
Every month | Clean the running surfaces1) | |
6 months | Check all connections for correct fastening and damage | |
6 months | Check that the guide rails are properly secured to the motor modules | |
Lock | Every month | Clean the running surfaces1) |
6 months | Check the lock for wear and damage | |
6 months | Check the lock for correct fastening | |
After each installation | Check the lock for correct fastening | |
If required | Apply a small quantity of lubricant2) to the running surfaces |