Disassembly
| |
Uncontrolled movers can cause serious injuries After removing the controller enable or switching off the supply voltage, movers can move in an uncontrolled manner on a vertical path and cause serious injuries to fingers due to crushing and to eyes due to splinters.
|
| |
Risk of injury when disassembling the movers Permanent magnets are installed in the magnetic plate sets of the movers. Be careful when disassembling the magnetic plate sets. Make sure that the magnetic plate sets do not magnetically attract one another with your hands in-between. If you don't take care during the disassembly, opposite magnetic plate sets may attract each other without warning and injure your hands. |
![]() | Do not remove components from the products Only Beckhoff Automation GmbH & Co. KG is permitted to remove components. Contact Beckhoff Service for further information. |
Removing the components from the machine
- Remove cables and electrical connections
- Loosen the fixing screws of the guide rails and the modules
- Remove the modules from the machine one after the other
- Transport the components to the workplace or storage place
Further information can be found in chapter Transport and storage.