Guide rails, 180° curved segment

The curved segments must be prepared for mounting on the modules. Further information can be found in chapter Guide rails, 180° curved segment.

Guide rails, 180° curved segment 1:

Simplified mounting

Beckhoff recommends applying a small amount of lubricant to the connecting surfaces and the inner running surfaces of the 180° curved segments before mounting. Greasing the curved segments facilitates mounting on the straight guide rails.

Beckhoff recommends the following lubricants:

Guide rails, 180° curved segment 2:
►Push the curved segment [1] onto the module [2]
Guide rails, 180° curved segment 3:
►Insert screws [1] with liquid threadlocker [2] into the curved segment [3] and hand-tighten
Guide rails, 180° curved segment 4:
►Push the curved segment [1] onto the module [2] and close the system
Guide rails, 180° curved segment 5:
►Insert screws [1] with liquid threadlocker [2] into the curved segment [3] and hand-tighten
Guide rails, 180° curved segment 6:

The hole [1] in the center of the guide rail is not used for fixing. The hole can be used to dismantle the curved segment.

Further information can be found in chapter Dismantling the guide rails, 180° curved segment.