Guide rails, 180° curved segment
The curved segments must be prepared for mounting on the modules. Further information can be found in chapter Guide rails, 180° curved segment.
![]() | Simplified mounting Beckhoff recommends applying a small amount of lubricant to the connecting surfaces and the inner running surfaces of the 180° curved segments before mounting. Greasing the curved segments facilitates mounting on the straight guide rails. |
Beckhoff recommends the following lubricants:
- Petrolatum when using movers without spring-loaded rollers
- Food grade grease NSF-H1 when using movers with spring-loaded rollers
- ►Push the curved segment [1] onto the module [2]
- ►Insert screws [1] with liquid threadlocker [2] into the curved segment [3] and hand-tighten
- ►Push the curved segment [1] onto the module [2] and close the system
- ►Insert screws [1] with liquid threadlocker [2] into the curved segment [3] and hand-tighten
The hole [1] in the center of the guide rail is not used for fixing. The hole can be used to dismantle the curved segment.
Further information can be found in chapter Dismantling the guide rails, 180° curved segment.