Straight EcoLine modules with plug connector

Notice

Limited number of turns

The connector may be rotated up to ten times through 180° to bring it into a safe latching position.

If you turn the connector more than ten times, the cables inside and the latching mechanism of the connector may be damaged and the connector may no longer be placed in a safe latching position.

Straight EcoLine modules with plug connector 1:

The module connector may be turned a maximum of ten times by 180°.

Straight EcoLine modules with plug connector 2:
►Position module [1] with the locating pins [2] in the elongated holes in the machine bed [3]
►Ensure that the connector [4] is positioned in the recess [5] of the machine bed
Straight EcoLine modules with plug connector 3:
►Hand-tighten the screw [1] with the washer [2] in the module [3]
►Make sure that the module [3] is slightly movable in the elongated holes