Magnetic plate set Mover 1
Magnetic plate set | Number of magnets | Suitable mover types | Mover type after mounting the magnetic plate set |
|---|---|---|---|
AT9001-1450-1640 | 4 | AT901x-x0xx-0450** | AT901x-x0xx-1450 |
AT901x-x0xx-1450 | AT901x-x0xx-1450 | ||
AT901x-x0xx-0550** | AT901x-x0xx-1450 | ||
AT901x-x0xx-1550 | AT901x-x0xx-1450 | ||
Mover Standard* from third-party manufacturers | Mover 1* from third-party manufacturers | ||
Mover 1* from third-party manufacturers | Mover 1* from third-party manufacturers | ||
AT9001-1550-1640 | 5 | AT901x-x0xx-0450** | AT901x-x0xx-1550 |
AT901x-x0xx-1450 | AT901x-x0xx-1550 | ||
AT901x-x0xx-0550** | AT901x-x0xx-1550 | ||
AT901x-x0xx-1550 | AT901x-x0xx-1550 | ||
Mover Standard* from third-party manufacturers | Mover 1 from third-party manufacturers | ||
Mover 1 from third-party manufacturers | Mover 1 from third-party manufacturers | ||
AT9001-1775-1640 | 7 | Mover Standard* from third-party manufacturers | Mover 1 from third-party manufacturers |
Mover 1 from third-party manufacturers | Mover 1 from third-party manufacturers | ||
AT9001-1AA0-1640 | 10 | Mover Standard* from third-party manufacturers | Mover 1 from third-party manufacturers |
Mover 1 from third-party manufacturers | Mover 1 from third-party manufacturers |
* | After mounting a magnetic plate set Mover 1, the Mover Standard assumes Mover 1 functionality and is recognized as servo axis 1. |
A 1.6 mm thick encoder flag is mounted on a magnetic plate of the magnetic plate set. If necessary, this must be replaced with a thicker or thinner encoder flag. Further information can be found in chapter Replacing the encoder flag.