Technical data

Technical data 1:

Position

Explanation

1

Lateral offset to the direction of travel [mm]

2

Height offset to direction of travel [mm]

3

Torques of the linear axes [Nm]


* When using a Beckhoff guide rail.

Offset to direction of travel* [mm]

Lateral 

≤ 0.1

In height

≤ 0.1

* When using a Beckhoff guide rail.

Maximum linear axis torque* [Nm]

X-axis Mx

50

Y-axis My

15

Z-axis Mz

10

Drive axis

6

* For standard modules and modules with integrated NCT functionality.
**For EcoLine modules.

Air gap in the direction of travel [mm]

Minimum 

0.5

Nominal value

1

Maximum 

3* | 1**