Checking the air gap
Checking the mover on the guide rail To check the air gap, the movers must be on the guide rail. The air gap of dismantled movers with spring-loaded rollers is always zero due to their design. |
The air gap between the suspension strut [1] and the base body [2] must be at least 0.1 mm.
- ►Insert a 0.1 mm feeler gauge blade [1] into the air gap [2] between the suspension strut and the base body
If the 0.1 mm feeler gauge blade cannot be inserted into the air gap, the rollers must be replaced.