Disassembly
Notice | |
Follow the correct sequence when dismantling the guide rollers Disassemble the guide rollers from the outside to the inside as described below. If you disassemble the guide rollers in a different sequence, this may result in damage to the mover and additional time expenditure. |
Disassembly sequence of the guide rollers
Sequence | Name | Number of items |
---|---|---|
A | Cylindrical guide roller 22 mm, with shoulder bolt M4 x20 [2] | 4 |
B | Cylindrical guide roller 25 mm, with bearing pin D5 x 23 [1] | 2 |
For more information on the position of the guide rollers, see the chapter Arrangement of the guide rollers on the mover.
- ►Pierce the sealing plug [1] and lever it out of the mover housing
- ►Hold the shoulder bolt [1] of the roller [2] with the angle pin wrench
- ►Remove nut [3]
Notice | |
Avoid jamming the shoulder bolt in the mover housing Pull the shoulder bolt straight out of the mover housing to avoid jamming. Tilting of the shoulder bolt can result in damage to the mover housing and additional time requirement. |
- ►Pull the shoulder bolt [1] with roller [2] and adjusting washer [3] straight out of the mover housing and remove to the side
- ►Disassemble the upper guide rollers in the same way
- ►Loosen the set screw [1] with a hexagon bit [+]
- ►Insert the pin punch [2] through the opening [3] in the mover housing
- ►Push the bearing pin [1] straight out of the mover housing by pressing the pin punch [2] and remove it to the side
- ►Remove the roller [3] from the mover housing to the side
- ►Disassemble the second lower roller in the same way
Notice | |
Avoid jamming the bearing pin in the mover housing Use a pin punch [+] to push the bearing pin straight out of the mover housing to prevent it from jamming. Tilting of the bearing pin can result in damage to the mover housing and additional expenditure of time. |
- ►Loosen the set screw [1] with a hexagon bit [+]
- ►Remove ESD brush [2]
Notice | |
Avoid damage due to the use of aggressive substances The guide rollers and the mover housing can be damaged if aggressive substances are used. Apply detergent to a clean, lint-free cloth. Never apply the cleaning agent directly to the components. Unsuitable cleaning agents can damage the components and considerably reduce the service life of the guide rollers. |
For heavy soiling, cleaning agent can be applied to a clean, lint-free cloth. Isopropanol cleaning agent can be used for cleaning.
- ►Clean the mover housing with a damp cloth after removing the guide rollers and the ESD brush