Checking the air gap
![]() | Checking the mover on the guide rail To check the air gap, the movers must be on the guide rail. The air gap of dismantled movers with spring-loaded rollers is always zero due to their design. |
The air gap between the suspension strut [1] and the base body [2] must be at least 0.1 mm.
- ►Insert a 0.1 mm feeler gauge blade [1] into the air gap [2] between the suspension strut and the base body
If the 0.1 mm feeler gauge blade cannot be inserted into the air gap, the rollers must be replaced.