Mounting

Notice

Mounting the correct encoder flag

The imprint on the encoder flag makes it easier to identify Mover Standard and Mover 1. When fitting the encoder flag, make sure that you fit the appropriate encoder flag for the relevant magnetic plate set.

Mounting 1:

Each magnetic plate set Mover 1 has a Mover 1 [1] engraving on the magnetic plate. When mounting the encoder flag, make sure that the correct encoder flag is mounted on the corresponding magnetic plate.

An encoder flag with Mover 1 [2] imprint must be mounted on a magnetic plate with Mover 1 [2] engraving. An encoder flag Mover Standard [3] must not be mounted on a magnetic plate with Mover 1 [1] engraving.

An encoder flag Mover Standard [3] must be mounted on a magnetic plate Mover Standard [4]. An encoder flag with Mover 1 [2] imprint must not be installed on a magnetic plate Standard Mover [4].

Mounting 2:
►Screw the encoder flag [1] to the magnetic plate with screws [2]
►Observe tightening torques:

Components

Tightening torque [Nm]

Screws, M3 x 4

0.8