Disassembly

WARNING

Keep the workplace free of metallic and magnetic materials

Make sure that your workplace is free of metallic and magnetic materials before positioning the mover. The permanent magnets of the movers can attract tools used to replace the magnetic plates.

If movers are attracted by metallic and magnetic parts, serious injuries to the fingers from crushing and in the eyes from splinters can result.

WARNING

Risk of injury during disassembly of the magnetic plates

Permanent magnets are installed in the magnetic plate sets of the movers. Be careful when disassembling the magnetic plate sets. Make sure that the magnetic plate sets do not magnetically attract one another with your hands in-between.

If you don't take care during the disassembly, opposite magnetic plate sets may attract each other without warning and injure your hands.

Disassembly 1:
►Remove screws [1]
►Remove magnetic plate [2]
Disassembly 2:
►Rotate mover [1] by 180 degrees
Disassembly 3:
►Remove screws [1]
►Remove magnetic plate [2] with encoder flag [3]