Guide rails

Components

Interval

Maintenance

Straight guide rails

6 months

Check all connections for correct fastening and damage

Every month

Clean the running surfaces

Permitted cleaning agent:
Isopropanol

As required

Apply a small quantity of lubricant to the running surfaces

Recommended lubricants:
Food grade grease NSF-H1* or petrolatum

6 months

Check the fastening of the guide rails to the modules

Every 2000 km*

Apply a small quantity of lubricant to the running surfaces

Recommended lubricants:
Food grade grease NSF-H1*

Curved rails

6 months

Check all connections for correct fastening and damage

Every month

Clean the running surfaces

Permitted cleaning agent:
Isopropanol

As required

Apply a small quantity of lubricant to the running surfaces

Recommended lubricants:
Food grade grease NSF-H1* or petrolatum

6 months

Check the fastening of the curved rails to the modules

Every 2000 km*

Apply a small quantity of lubricant to the running surfaces

Recommended lubricants:
Food grade grease NSF-H1*

Lock

6 months

Check the lock for damage

Every month

Clean the running surfaces

Permitted cleaning agent:
Isopropanol

As required

Apply a small quantity of lubricant to the running surfaces

Recommended lubricants:
Food grade grease NSF-H1* or petrolatum

6 months

Check the lock for correct fastening

If it has been opened and remounted

Check the lock for correct fastening

* only for movers AT9014-x0xx-x550