Mover
Components | Interval | Maintenance |
---|---|---|
Base body | 60,000 km* | Replace base body and guide rollers |
Guide rollers | 3 months | Check guide rollers for wear and damage |
30,000 km* | Replace guide rollers | |
60,000 km* | Replace guide rollers and base body | |
Magnetic plates | 6 months | Check the magnetic plates for abrasion and damage |
Encoder flag | 6 months | Check encoder flag for correct attachment |
6 months | Check that the encoder flag is not rubbing against the module sensors | |
ESD brush | 6 months | Check ESD brush for correct attachment |
6 months | Check the distance between the ESD brush and the guide rail. The ESD brush must touch the guide rail. | |
Air gap* | As required | Check the air gap between the suspension strut and base body. The air gap must be at least 0.1 mm. |
* only for movers AT9014-x0xx-x550
|
After checking the components, it may be necessary to replace them. Further information can be found in chapter Maintenance work on the mover.