Requirements
- Components show no signs of damage
- System is correctly aligned
- The magnetic plates and encoder flag of the mover are correctly aligned with the modules
- Pretension of the mover with spring-loaded rollers is set correctly
- Screw connections of the components are correctly tightened
- Mechanical protective equipment is correctly installed
- Electrical protective equipment is correctly installed
- Wiring and cables are installed correctly
- Machine bed is correctly grounded
- Number of movers with magnetic plate set Mover 1 is correct
- Tools and attachments are functional
- Protection against moving and live parts is correctly installed
- Current version of TwinCAT XAE and TF5850 software is installed on an IPC
- 24 V control voltage is connected
- 48 V supply voltage is connected
If movers with mounted NCT electronics are used:
- NCT electronics are removed before initial commissioning
- NCT electronics are removed before commissioning new motion profiles
Further information on the requirements can be found in chapters Mechanical installation, Electrical installation and Replacing NCT electronics.