Checking the roller
When transporting the roller set, the adjusting washer may move in the roller. In this case proceed as described below.
Notice | |
Incorrect position of the adjusting washer in the roller A slipped adjusting washer inside the roller can cause the shoulder bolt not to pass smoothly through the roller during mounting, damaging the roller lining and affecting the running characteristics of the mover. Bring the adjusting washer into the correct position. |
- ►Use a slot screwdriver to push the adjusting washer [1] centrally between the two ball bearings [2] of the roller lining [3]
- ►Insert the shoulder bolt through the roller again
- ►Check for tight fit