Mover alignment
Item number | Name |
---|---|
1 | XY axes of the mover |
2 | Sticker with coordinate origin |
When placing the movers, make sure that the XY axes of the mover [1] correspond to the XY axes of the tile. The coordniate origin of the tile is used for orientation. For more information see chapter Mounting.
Also make sure that you position the movers as parallel as possible to the outer edges of the tiles.
| |
Do not reach under the movers When placing a mover on the tiles, do not reach under the mover with your fingers. Magnetic attraction both between the mover and the tile and between two movers can result in serious injury to fingers from crushing and to eyes from splinters. |
Notice | |
Check the underside of the mover for adhesive deposits Check the underside of the mover for adhesive deposits and clean it if necessary. Adhesive deposits can cause damage to the tile surface. |
- ►Take the mover [1] out of the transport securing device [2] with a straight upward movement
- ►Position the mover [1] straight in the center of the adjacent tile [3]
- ►Make sure that your fingers are not underneath the tile [3] and that the mover [1] has sufficient distance to other movers
- ►Remove the transport securing device [1]
- ►Position the remaining movers on the tiles in the same way