Stator surface
Notice | |
Damage to the stator surface caused by small magnetic parts Do not allow any small magnetic parts, such as washers, metal shavings, or metal dust, to get onto the stator surface. Movers can attract and pick up small magnetic parts. Small magnetic parts adhering to the mover can damage the stator surface and cause a system failure.
|
Notice | |
Damage to the stator surface due to mechanical stress Do not place any tools or objects with sharp, pointed, or small contact surfaces on the stator surface or press them against it. Point loads or loads applied by sharp edges can damage the stator surface and the coils beneath it.
|
The stator surface of the tiles must not be damaged. Damaged tiles must be replaced immediately. Avoid:
- Placing and setting down objects and tools on the stator surface
- Pressing objects and tools against the stator surface
- Applying pressure to movers that are resting on the stator surface
- Point loads, such as those caused by screwdrivers, grippers, probe tips, pins, or sharp-edged components
- Contaminants on the stator surface
- Contaminants on the underside of the movers
- Small magnetic parts on the stator surface, the underside of the movers, and near the system.
For assembly steps and press-fitting operations, suitable fixtures must be installed to absorb the resulting forces, either through the mover or at locations outside the stator surface. Perform press-fitting operations only on tool carriers that have been set down. Further information can be found in chapter Press-in processes and pressing positions.