Mover

WARNING

Do not position the mover until the electrical installation has been completed

The movers may only be positioned once part 1 of the mechanical installation and the electrical installation have been completed. Perform a tile system test before positioning the movers.

Failure to do so may result in serious injury to fingers from crushing or to eyes from splinters.

WARNING

Wear safety goggles and gloves

The movers can have strong magnetic attraction to each other or other metallic objects. Splinters can form if magnets collide.

Failure to do so may result in serious injury to fingers and eyes.

WARNING

Remove each mover individually from the box

If you take two movers out of the box and the distance between the movers is too small, the movers can attract each other.

If the movers attract each other and collide, serious injuries to the fingers from crushing and in the eyes from splinters can result.

WARNING

Do not reach under the mover with your fingers

When carrying a mover or placing it on the system, do not reach under the mover with your fingers.

Failure to do so can result in severe crushing and injury to fingers.

WARNING

Movers contain strong permanent magnets

The permanent magnets contained are arranged in so-called Hallbach arrays, which ensure that the magnetic field on the underside of the mover is significantly stronger than on the top of the mover. The field of the permanent magnets is present even when the power supply is switched off.

If the movers attract each other and collide, serious injuries to the fingers from crushing and in the eyes from splinters can result.